Datalogic ® Zurücksetzen - Boot

Datalogic ® Soft - Hard - Factory Reset
Datalogic Formula Soft Reset (Warm Boot)

Datalogic Formula Soft Reset - Warm Boot

1. Pressing SCAN + ON/OFF keys simultaneously.


Datalogic Blackjet Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic Blackjet Soft Reset - Warm Boot

1. Pressing F1 + SCAN + On/Off buttons simultaneously.


Datalogic Blackjet Hard Reset - Cold Boot

1. Pressing F1 + SCAN + F2 + On/Off buttons simultaneously.

Datalogic Blackjet Factory Reset

1. Perform a Cold Boot.
2. Quickly release all the buttons when the screen goes black.
3. Within 1 second, press and hold down ESC + 0 keys until the left orange LED starts blinking.
4. Release the ESC and 0 buttons.
5. Enter 1 to proceed with the clean boot sequence.
   Enter 0 to cancel the clean boot and proceed with a cold boot.

Datalogic Pegaso Soft - Hard Reset (Warm - Cold Boot)

Datalogic Pegaso Soft Reset - Warm Boot

Method 1:
1. Press and hold the Power button until the device turns off.
2. Wait a couple of seconds.
3. Hold down the Power button again to switch the cell phone back on.

Method 2:
1. Remove the back cover and the battery for a few seconds.
2. Put the battery and the cover back in.
3. Turn on the phone by holding the Power button.




Datalogic Pegaso Hard Reset - Cold Boot

1. Hold down the Power button in order to switch off the mobile phone.
2. Find and select Settings.
3. Afterwards choose Security and tap Factory Settings.
4. Highlight option Restore factory default and confirm be tapping OK.
5. To begin the whole operation enter the confirmation code: 1234.
6. The hard reset is performed.

Datalogic SkorpioX3 Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic SkorpioX3 Soft Reset - Warm Boot

1. Press and hold the Yellow Key, Blue Key and ESC Button simultaneously.


Datalogic SkorpioX3 Hard Reset - Cold Boot

1. Turn off the Skorpio X3 by pressing the ON/OFF Power button.
2. Pull the battery latch down and remove the battery pack.
3. Simultaneously press the SCAN key and the Reset button in the battery compartment.
4. Insert the battery pack.
5. Turn on the Skorpio X3 by pressing the ON/OFF Power button.

Datalogic SkorpioX3 Factory Reset

1. Perform a Cold Boot.
2. Press and hold down the Esc + 0 keys simultaneously, prompty after resetting.
3. A dialog box will appear asking for confirmation. Press the Enter Key.

Datalogic Skorpio Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic Skorpio Soft Reset - Warm Boot

1. Press the Scan Button, Yellow Key, and Blue Key at the same time.
2. Release the keys once the Datalogic Splash Screen appears.


Datalogic Skorpio Hard Reset - Cold Boot

1. Press the Scan Button, Yellow Key, Blue Key, and the Down Arrow Key at the same time.
2. Release the keys once the Datalogic Splash Screen appears.

Datalogic Skorpio Factory Reset

1. Perform a Cold Boot.
2. Quickly release all the buttons when the screen goes black.
3. Within 1 second, press and hold down ESC + 0 keys until the left orange LED starts blinking.
4. Release the ESC and 0 buttons.
5. Enter 1 to proceed with the clean boot sequence.
   Enter 0 to cancel the clean boot and proceed with a cold boot.

Datalogic Memor X3 Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic Memor X3 Soft Reset - Warm Boot

1. Press the ESC button and the Power button simultaneously.


Datalogic Memor X3 Hard Reset - Cold Boot

1. Press the ESC + ENT + Power buttons simultaneously.

Datalogic Memor X3 Factory Reset

1. Perform a Cold Boot.
2. Quickly release all the buttons when the screen goes black.
3. Within 1 second, press and hold down ESC + 0 keys until the left orange LED starts blinking.
4. Release the ESC and 0 buttons.
5. Enter 1 to proceed with the clean boot sequence. Enter 0 to cancel the clean boot and proceed with a cold boot.


Datalogic Memor Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic Memor Soft Reset - Warm Boot

1. Press and hold the ESC button and the Power button at the same time.


Datalogic Memor Hard Reset - Cold Boot

1. Press and hold the ESC, Joystick and Power buttons at the same time.

Datalogic Memor Factory Reset

1. Perform a Cold Boot.
2. Quickly release all the buttons when the screen goes black.
3. Within 1 second, press and hold down ESC + 0 keys until the left orange LED starts blinking.
4. Release the ESC and 0 buttons.
5. Enter 1 to proceed with the clean boot sequence.
   Enter 0 to cancel the clean boot and proceed with a cold boot.

Datalogic Joya Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic Joya Soft Reset - Warm Boot

Method 1:
1. Simultaneously press F1 + F2 + ENTER.

Method 2:
2. Press with a pin or a paper clip the cold boot button on the back of the mobile computer.


Datalogic Joya Hard Reset - Cold Boot

1. Simultaneously press SCAN + ENTER.

Datalogic Joya Factory Reset

1. Perform a Cold Boot.
2. As soon as the device is rebooting, press simultaneously ESC + ENTER,
   holding both keys down for few seconds.
3. Press ENTER to confirm.


Datalogic ELF Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic ELF Soft Reset - Warm Boot

1. Press and hold the Yellow Key, Blue Key and Red Disconnect Button simultaneously.


Datalogic ELF Hard Reset - Cold Boot

1. Turn off the Elf by pressing the ON/OFF Power button.
2. Pull the battery latch down and remove the battery pack.
3. Press the Reset button.
4. Insert the battery pack.
5. Turn on the Elf by pressing the ON/OFF Power button.

Datalogic ELF Factory Reset

1. Perform a Cold Boot.
2. Press and hold down the 0 and Red Disconnect buttons simultaneously and then press the ON/OFF key.
3. A dialog box will appear asking for confirmation. Press the Enter button.


Datalogic LYNX Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic LYNX Soft Reset - Warm Boot

1. Press and hold the Yellow Key, Blue Key and Red Disconnect Button simultaneously.


Datalogic LYNX Hard Reset - Cold Boot

1. Turn off the Lynx by pressing the ON/OFF key.
2. Pull the battery latch down and remove the battery pack.
3. Press the Reset button.
4. Insert the battery pack.
5. Turn on the Lynx by pressing the ON/OFF Power button.

Datalogic LYNX Factory Reset

1. Perform a Warm Boot.
2. Before the splash screen appears, press and hold down the 0 and Red Disconnect buttons simultaneously.
3. A dialog box will appear asking for confirmation. Press the Enter Key to confirm.
   If you wish to cancel the clean boot, press Esc by pressing Blue + Red Disconnect buttons.

Datalogic Kyman Soft - Hard - Factory Reset (Warm - Cold Boot)

Datalogic Kyman Soft Reset - Warm Boot

1. Pressing F1 + SCAN + On/Off buttons simultaneously.


Datalogic Kyman Hard Reset - Cold Boot

1. Pressing F1 + SCAN + F2 + On/Off buttons simultaneously.

Datalogic Kyman Factory Reset

1. Perform a Cold Boot.
2. Quickly release all the buttons when the screen goes black.
3. Within 1 second, press and hold down ESC + 0 keys until the left orange LED starts blinking.
4. Release the ESC and 0 buttons.
5. Enter 1 to proceed with the clean boot sequence.
   Enter 0 to cancel the clean boot and proceed with a cold boot.


Falcon X3 / X3+ Soft - Hard - Factory Reset (Warm - Cold Boot)

Falcon X3 / X3+ Soft Reset - Warm Boot

1. Press and hold the Yellow Key, Blue Key and ESC Button simultaneously.


Falcon X3 / X3+ Hard Reset - Cold Boot

1. Turn off the Falcon X3 by pressing the ON/OFF key.
2. Pull the battery latch down and remove the battery pack.
3. Press the Reset button.
4. Insert the battery pack.
5. Turn on the Falcon X3 by pressing the ON/OFF Power button.

Falcon X3 / X3+ Factory Reset

1. Perform a Cold Boot.
2. Press and hold down the 0 and ESC keys simultaneously and then press the ON/OFF Power button.
3. A dialog box will appear asking for confirmation. Press the Enter Key.

Falcon 4220 Soft - Hard Reset (Warm - Cold Boot)

Falcon 4220 Soft Reset - Warm Boot

1. Press and hold the Reset Button simultaneously.




Falcon 4220 Hard Reset - Cold Boot

1. Simultaneously press the Reset button with the stylus while pressing the FN2 button.

Falcon 4410 Soft - Hard Reset (Warm - Cold Boot)

Falcon 4410 Soft Reset - Warm Boot

26-key Falcon:
1. Press and hold Fn + Alpha +Bksp buttons.

48-key Falcon:
1. Press and hold Ctrl + Alt +Bksp buttons.

52-key Falcon:
1. Press and hold Alt + Fn +F1 buttons.

Hold down (1) and (2) … Then press (3):




Falcon 4410 Hard Reset - Cold Boot

1. Insert a paper clip into the cold Reset button while pressing the Power button.




Falcon 4420 Soft - Hard Reset (Warm - Cold Boot)

Falcon 4420 Soft Reset - Warm Boot

26-key Falcon:
1. Press and hold Fn + Alpha +Bksp buttons.

48-key Falcon:
1. Press and hold Ctrl + Alt +Bksp buttons.

52-key Falcon:
1. Press and hold Alt + Fn +F1 buttons.

52-key NU Falcon:
1. Press and hold Ctrl + Alt +Del buttons.

Hold down (1) and (2) … Then press (3):




Falcon 4420 Hard Reset - Cold Boot

1. Insert a paper clip into the cold Reset button while pressing the Power button.





PowerScan PBT7100 Factory Reset

PowerScan PBT7100 Factory Reset

1. Scan the Restore Custom Default Configuration barcode below.
   This will restore the custom configuration for the currently active interface:




    If you aren't sure what programming options are in your imager, or you've changed some options
    and want to restore the Factory Configuration, you have two options.
    You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below: